Weight accumulation, continued – Fairbanks NexWeigh User Manual
Page 66

Section 6: Operations
04/14
66
51216 -- Rev. 6
6.3.5. Weight Accumulation, Continued
C. Port 1 set to Auto and Aout set to no.
1. After weight is applied, and if the weight is greater than the accumulate
threshold, the instrument will flash all the green ACCEPT LEDs for one second
showing that the weight has been stored as an accumulation.
2. If a print is to occur, press
and port 1 will transmit the following:
“Weight nn = wwwwww uu GR/NT”
nn is the number of the current accumulated weight in numerical order.
wwwwww is the last accumulated weight.
uu is the unit of weight accumulated.
GR or NT represent whether accumulated weight is gross or net respectively.
3. Weight on the scale must now be removed to less than .5 grads before the
next accumulation can occur.
4. Repeat steps 1-3 to continue accumulations (up to 99).
D. Port 1 set to button and Aout set to yes.
1. After weight is applied, and if the weight is greater than the accumulate
threshold press
PROGRAM/ENTER
. The instrument will check to ensure
there is no motion. If scale is in motion, the instrument will wait up to 10
seconds for motion to stop. If the weight is not stable after 10 seconds, the
scale will disregard the request for accumulation. If stability occurs, the green
ACCEPT LEDs will flash for 1 second showing that the weight has been stored
as an accumulation.
2. If a print is to occur, press
and port 1 will transmit the following:
“Weight nn = wwwwww uu GR/NT”
nn is the number of the current accumulated weight in numerical order.
wwwwww is the last accumulated weight.
uu is the unit of weight accumulated.
GR or NT represent whether accumulated weight is gross or net respectively.
3. Weight on the scale must now be removed to less than .5 grads before the
next accumulation can occur.
4. Repeat steps 1-3 to continue accumulations (up to 99).