Configuration menu, continued d rate – Fairbanks NexWeigh User Manual
Page 30
Section 4: Programming Configuration
04/14
30
51216 -- Rev. 6
4.5.2. Configuration Menu, Continued
d rAtE:
Programming the display update rate: The times between display
updates in seconds. The display will indicate
d rAtE
and then the current setting.
Press
OVER/UNDER/NEXT
or
UNITS
to scroll up, or
TARE
to scroll down
through the available choices. Press
PROGRAM/ENTER
to enter the selection.
Available selections are:
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
P1:
Output format of Port1, GTN or net only: This determines whether the output
from Port1 will be transmitted as a net weight only or a gross/tare/net weighment.
The display will indicate
P1
followed by the current setting. Press
OVER/UNDER/NEXT
,
UNITS
or
TARE
to change the selection. Press
PROGRAM/ENTER
to enter the selection. Available choices are:
Gtn
nEt
P2:
Output format of
Port2
,
GTN
or
net only
: This determines whether the
output from Port2 will be transmitted as a net weight only or a gross/tare/net
weighment. The display will indicate
P1
followed by the current setting. Press
OVER/UNDER/NEXT
,
UNITS
or
TARE
to change the selection. Press
PROGRAM/ENTER
to enter the selection. Available choices are:
Gtn
nEt
The NexWeigh instrument will now return to the
ConFiG
prompt. Navigate to the
desired menu heading to continue programming, or to
DONE
to finish.