beautypg.com

Check weighing, continued – Fairbanks NexWeigh User Manual

Page 72

background image

Section 6: Operations

04/14

72

51216 -- Rev. 6

6.3.7. Check Weighing, Continued

16. The entire UNDER bar graph and the first segment of the ACCEPT bargraph

will be illuminated. The captured weight value is displayed with the leftmost
digit flashing. This is the start of ACCEPT point. If the weight displayed
needs to be altered, press

UNITS

to increase the digit, or press

1

to

decrease it. Press

OVER/UNDER/NEXT

to move flashing digit to the right,

or press

TARE

to move it to the left. Press

PRINT

to move the decimal

point to the right. Press

ZERO

to display all zeroes on the display. When the

correct start of accept value is displayed, press

PROGRAM/ENTER

.

17. The first segment of the UNDER will be illuminated along with a number with

the leftmost digit flashing. This is the start of UNDER point. Using the same
procedure as identified in step 16 above, enter the correct value for the
beginning of the under range, this could be 0. When the correct start of under
value is displayed, press

PROGRAM/ENTER

.

18. The entire UNDER bargraph, the entire ACCEPT, and the first segment of the

OVER bargraph will be illuminated. The captured weight value is displayed
with the leftmost digit flashing. This is the end of ACCEPT point. If required
using the same procedure as identified in step 16 above, enter the correct
value for the end of the accept range. When the correct end of accept value is
displayed, press

PROGRAM/ENTER

.

19. The entire UNDER bar graph, the entire ACCEPT, and the entire OVER bar

graph will be illuminated. The last weight value is displayed with the leftmost
digit flashing. This is the end of OVER point. Using the same procedure as
identified in step 16 above, enter the correct value for the end of the accept
range. When the correct end of over value is displayed, press

PROGRAM/ENTER

.

20. The instrument will briefly display CSAvEd, then return to the weigh mode with

the most recently configured recipe active.

21. If hAnd Y is selected, the first segment of the UNDER bargraph will be

illuminated. A previously programmed weight value is displayed with the
leftmost digit flashing. This is the start of UNDER point. If the weight
displayed needs to be altered, press

UNITS

to increase the digit, or press

1

to decrease it. Press

OVER/UNDER/NEXT

to move flashing digit to the

right, or press

TARE

to move it to the left. Press

PRINT

to move the

decimal point to the right. Press

ZERO

to display all zeroes on the display.

When the correct start of under value is displayed, press

PROGRAM/ENTER

.