6.3.7. Check Weighing, Continued
16. The entire UNDER bar graph and the first segment of the ACCEPT bargraph
will be illuminated. The captured weight value is displayed with the leftmost
digit flashing. This is the start of ACCEPT point. If the weight displayed
needs to be altered, press
UNITS
to increase the digit, or press
1
to
decrease it. Press
OVER/UNDER/NEXT
to move flashing digit to the right,
or press
TARE
to move it to the left. Press
to move the decimal
point to the right. Press
ZERO
to display all zeroes on the display. When the
correct start of accept value is displayed, press
PROGRAM/ENTER
.
17. The first segment of the UNDER will be illuminated along with a number with
the leftmost digit flashing. This is the start of UNDER point. Using the same
procedure as identified in step 16 above, enter the correct value for the
beginning of the under range, this could be 0. When the correct start of under
value is displayed, press
PROGRAM/ENTER
.
18. The entire UNDER bargraph, the entire ACCEPT, and the first segment of the
OVER bargraph will be illuminated. The captured weight value is displayed
with the leftmost digit flashing. This is the end of ACCEPT point. If required
using the same procedure as identified in step 16 above, enter the correct
value for the end of the accept range. When the correct end of accept value is
displayed, press
PROGRAM/ENTER
.
19. The entire UNDER bar graph, the entire ACCEPT, and the entire OVER bar
graph will be illuminated. The last weight value is displayed with the leftmost
digit flashing. This is the end of OVER point. Using the same procedure as
identified in step 16 above, enter the correct value for the end of the accept
range. When the correct end of over value is displayed, press
PROGRAM/ENTER
.
20. The instrument will briefly display CSAvEd, then return to the weigh mode with
the most recently configured recipe active.
21. If hAnd Y is selected, the first segment of the UNDER bargraph will be
illuminated. A previously programmed weight value is displayed with the
leftmost digit flashing. This is the start of UNDER point. If the weight
displayed needs to be altered, press
UNITS
to increase the digit, or press
1
to decrease it. Press
OVER/UNDER/NEXT
to move flashing digit to the
right, or press
TARE
to move it to the left. Press
to move the
decimal point to the right. Press
ZERO
to display all zeroes on the display.
When the correct start of under value is displayed, press
PROGRAM/ENTER
.