Section 4: Programming Configuration

04/14

31

51216 -- Rev. 6

4.5.3. APP Menu

7. Press and hold the

PROGRAM/ENTER

key or press

S1

on the main PCB to

display

SEtUP

.

8. Press

UNITS

or

OVER/UNDER/NEXT

twice to display

APP

.

9. Press the

PROGRAM/ENTER

key to enter

APP

menu.

X.XXuPd:

Display microvolts per division: This is a reference to display the

current microvolts per division. The display will indicate X.XXuPd where X.XX is a
numeric value of the microvolts per division. Press any front panel pushbutton other
than

B/G / NET

to continue.

4-20:

4-20mA analog output setting: Enables or disables the output. The display

will indicate 4-20 followed by the current setting of

Y

for enable and

N

for disable.

Press

OVER/UNDER/NEXT

,

UNITS

or

TARE

to change the selection. Press

PROGRAM/ENTER

to enter the selection.

ACC:

Accumulate feature enabled: Enables or disables the accumulate feature.

The display will indicate

ACC

followed by the current setting of

Y

for enable and

N

for disable. Press

OVER/UNDER/NEXT

,

UNITS

or

TARE

to change the

selection. Press

PROGRAM/ENTER

to enter the selection.

A thLd:

Autoprint and accumulate threshold: This is the number of divisions the

instrument must meet or exceed for an autoprint or an auto-accumulation to occur.
The display will indicate

A thld

, followed by the current setting in divisions with the

left digit flashing. Press

UNITS

to increase the digit, press the

1

key to decrease

the flashing digit. Press

OVER/UNDER/NEXT

to move the flashing digit to the

right or press the

TARE

to move it to the left. Press

PROGRAM/ENTER

when

the display shows the correct threshold setting. The acceptable range is 1 to 1000
and default value is

10

divisions.