beautypg.com

Setup menu, continued baud, Dbit, Opti – Fairbanks NexWeigh User Manual

Page 24: Opda, Opid

background image

Section 4: Programming Configuration

04/14

24

51216 -- Rev. 6

4.5.1. Setup Menu, Continued

bAud:

Programming Port 2 baud rate: The display will indicate

bAud

then the

current setting. Press

OVER/UNDER/NEXT

or

UNITS

to scroll up, or

TARE

to

scroll down through the available choices. Press

PROGRAM/ENTER

to enter the

selection. Available selections are:

300

600

1200

2400

4800

9600

19200

38400

57600

115200

dbit:

Programming Port 2 data bits: The display will indicate

dbit X

where

X

is

either

7

or

8

. Press

OVER/UNDER/NEXT

,

UNITS

, or

TARE

to select proper

value. Press

PROGRAM/ENTER

to enter proper selection.

P:

Programming Port 2 Parity setting: The display will indicate

P

along with the current

setting. Press

OVER/UNDER/NEXT

,

UNITS

or

TARE

to change the selection.

Press

PROGRAM/ENTER

to enter the selection. Available selections are:

P nonE

P odd

P EvEn

oPti:

Include time data with transmitted data: This determines whether or not to

include the time in the data string for Port 2. Display will indicate

oPti

followed by

the current selection of

Y

for yes to include, or n for no to exclude. Press

OVER/UNDER/NEXT

,

UNITS

or

TARE

to change the selection. Press

PROGRAM/ENTER

to enter the selection.

oPdA:

Include date data with transmitted data: This determines whether or not to

include the date in the data string for Port 2. Display will indicate

oPdA

followed by

the current selection of

Y

for yes to include, or n for no to exclude. Press

OVER/UNDER/NEXT

,

UNITS

or

TARE

to change the selection. Press

PROGRAM/ENTER

to enter the selection.

oPId:

Include ID data with transmitted data: This determines whether or not to

include the ID in the data string for Port 2. Display will indicate

oPId

followed by the

current selection of

Y

for yes to include, or

n

for no to exclude. Press

OVER/UNDER/NEXT

,

UNITS

or

TARE

to change the selection. Press

PROGRAM/ENTER

to enter the selection.