Weight accumulation, continued – Fairbanks NexWeigh User Manual
Page 67
Section 6: Operations
04/14
67
51216 -- Rev. 6
6.3.5. Weight Accumulation, Continued
E. Port 1 set to button and Aout set to no.
After weight is applied, and if the weight is greater than the accumulate threshold
press
PROGRAM/ENTER
. The instrument will check to ensure there is no
motion. If scale is in motion, the instrument will wait up to 10 seconds for motion to
stop. If the weight is not stable after 10 seconds, the scale will disregard the request
for accumulation. If stability occurs, the green ACCEPT LEDs will flash for 1 second
showing that the weight has been stored as an accumulation.
1. If a print is to occur, press
and port 1 will transmit the following:
“Weight nn = wwwwww uu GR/NT”
nn is the number of the current accumulated weight in numerical order.
wwwwww is the last accumulated weight.
uu is the unit of weight accumulated.
GR or NT represent whether accumulated weight is gross or net respectively.
2. Weight on the scale must now be removed to less than .5 grads before the
next accumulation can occur.
3. Repeat steps 1-3 to continue accumulations (up to 99).
F. Displaying Accumulated Weight and Count.
1. Press and release
OVER/UNDER/NEXT
The instrument will alternately
display the total accumulated weight and the number of accumulations for two
seconds each. The count is left justified followed by ACC, and the total weight
is right justified.
2. The instrument will continue to alternately display the weight and count for 30
seconds or until
OVER/UNDER/NEXT
is pressed again
Note: The instrument must be displaying gross zero to display totals. An error of
“not 00” will display if weight is not removed.