Fairbanks NexWeigh User Manual
Page 51

Section 5: Serial I/O
04/14
51
51216 -- Rev. 6
5.4.8. NexWeigh Serial Commands and Definitions,
Continued
u)
Set Weight Display mode for Check weigh
Definition: Used to set the display weight number yes or no parameter for a
particular check weigh recipe.
Command: ‘SWD’ ‘recipe’ ‘value’
Options: 1,2,3,4
Options: Y,N
Sample Command: "SWD 1 Y\r"
Sample Command: "SWD 2 N\r"
v)
Set Recipe Enable for Check weigh
Definition: Used to set the recipe enable/disable parameter for a particular check
weigh recipe.
Command: ‘SRE’ ‘recipe’ ‘mode’
Options: 1,2,3,4
Options: E,D
Sample Command: "SRE 1 E\r"
Sample Command: "SRE 2 D\r"
w)
Set Recipe Track gross or net for Check weigh
Definition: Used to set the recipe weight track parameter as gross or net for a
particular check weigh recipe.
Command: ‘SRT’ ‘recipe’ ‘mode’
Options: 1,2,3,4
Options: G,N
Sample Command: "SRT 1 G\r"
Sample Command: "SRT 2 N\r"
x)
Set Tare Mode
Definition: Used to set the Auto tare enable parameter for the scale.
Command: ‘STM’ ‘mode’
Options: ON, OFF, ON-CLR
Sample Command: "STM ON\r"
y)
Set Filter Level
Definition: Used to set scale’s filter size. Number of readings averaged. Only valid
settings allowed.
Command: ‘SFL’ ‘readings’
Options:
1, 3, 5, 11, 15, 20, 30, 50
Sample Command: "SFL 11 \r"