beautypg.com

Configuration menu, continued cust – Fairbanks NexWeigh User Manual

Page 27

background image

Section 4: Programming Configuration

04/14

27

51216 -- Rev. 6

4.5.2. Configuration Menu, Continued

CuSt:

Custom units. The display will indicate CuSt and the current selection,

either

Y

for enable or

N

for disable. Press

OVER/UNDER/NEXT

,

UNITS

or

TARE

to change the selection. Press

PROGRAM/ENTER

to enter the selection.

NOTE:

When custom units are active, units LED instruments are off in the weigh

mode.

AZt:

Programming the Automatic Zero Tracking band: (this feature will maintain

zero when small amounts of material are placed on the scale, such as rain, snow,
debris, etc.) The display will indicate

AZt X

where

X

is the current setting. Press

OVER/UNDER/NEXT

,

UNITS

or

TARE

to change the selection. Press

PROGRAM/ENTER

to enter the selection. Available selections are:

OFF

Function is not active.

0.5

Half (½) of a division / increment / graduation.

1

One (1) division / increment / graduation.

3

Three (3) divisions / increments / graduations.

*

Underline identifies the program default.

bAL:

Programming the motion band (the range in divisions/increments/graduations

that weight must be stable before a print, zero, or tare function will be allowed). The
display will indicate

bAL X

where

X

is the current setting. Press

OVER/UNDER/NEXT

,

UNITS

or

TARE

to change the selection. Press

PROGRAM/ENTER

to enter the selection. Available selections are:

OFF

Function is not active.

0.5

Half (½) of a division / increment / graduation.

1

One (1) division / increment / graduation.

3

Three (3) divisions / increments / graduations.

*

Underline identifies the program default.