Fairbanks NexWeigh User Manual
Page 50
Section 5: Serial I/O
04/14
50
51216 -- Rev. 6
5.4.8. NexWeigh Serial Commands and Definitions,
Continued
p)
Set Units of Record for Check weigh
Definition: Used to set the units of record parameter for a particular check weigh
recipe. Must be a Mass standard, lb/oz and custom not allowed. Must be set before
entering the actual weight limits for the ranges.
Command: ‘SUR’ ‘recipe’ ‘unit’
Options: 1,2,3,4
Options: l=lb, k=kg, g=g, o=oz
Sample Command: "SUR 1 k \r"
q)
Set Start of Under for Check weigh
Definition: Used to set the start of underweight parameter for a particular check
weigh recipe. Value is a weight in the units of record set earlier.
Command: ‘SSU’ ‘recipe’ ‘value’
Options: 1,2,3,4
Options: decimal weight value
Sample Command: "SSU 1 12.57 \r"
r)
Set Start of Accept for Check weigh
Definition: Used to set the start of accept weight parameter for a particular check
weigh recipe. Value is a weight in the units of record set earlier.
Command: ‘SSA’ ‘recipe’ ‘value’
Options: 1,2,3,4
Options: decimal weight value
Sample Command: "SSA 1 14.1 \r"
s)
Set Start of Over for Check weigh
Definition: Used to set the start of over weight parameter for a particular check weigh
recipe. Value is a weight in the units of record set earlier.
Command: ‘SSO’ ‘recipe’ ‘value’
Options: 1,2,3,4
Options: decimal weight value
Sample Command: "SSO 1 16.45 \r"
t)
Set End of Over for Check weigh
Definition: Used to set the end of over weight parameter for a particular check weigh
recipe. Value is a weight in the units of record set earlier.
Command: ‘SEO’ ‘recipe’ ‘value’
Options: 1,2,3,4
Options: decimal weight value
Sample Command: "SEO 1 18.69 \r"