Section 5: Serial I/O
04/14
53
51216 -- Rev. 6
5.4.8. NexWeigh Serial Commands and Definitions,
Continued
ff)
Set Primary Gradsize
Definition: Used to set the primary gradsize for the scale. Only valid settings allowed.
Command: ‘SPG’ ‘value’
Options:
decimal value, 0.0001 to 500
Sample Command: "SPG 0.01 \r"
gg)
Set Primary Units
Definition: Used to set the primary units for the scale. Only valid settings allowed, no
lboz or custom.
Command: ‘SPU’ ‘unit’
Options:
l=lb, k=kg, g=g, o=oz
Sample Command: "SPU o \r"
hh)
Set Enabled Unit
Definition: Used to enable or disable a unit from the enabled units parameter for the
scale. Only valid settings allowed.
Command: ‘SEU’ ‘unit’ ‘mode’
Options:
l=lb, k=kg, g=g, o=oz, z=lb/oz, c=custom
Options:
E,D
Sample Command: "SEU l E \r"
Sample Command: "SEU k E \r"
Sample Command: "SEU o D \r"
Sample Command: "SEU g D \r"
Sample Command: "SEU z D \r"
Sample Command: "SEU c D \r"
ii)
Set Peak Hold Enable
Definition: Used to enable or disable peak hold feature for the scale.
Command: ‘SPH’ ‘mode’
Options:
E,D
Sample Command: "SPH D \r"
jj)
Set Time
Definition: Used to set the time in the RTC.
Command: STI
Options:
Military format 00:00 to 23:59
Sample Command: "STI 12:34\r"