App menu, continued aout, Beep, C-fact – Fairbanks NexWeigh User Manual
Page 32
Section 4: Programming Configuration
04/14
32
51216 -- Rev. 6
4.5.3. APP Menu, Continued
AOut:
Autoprint and autoaccumulate output: This setting will determine whether
the instrument will autoprint during an automatic accumulation. This setting is only
active if port 1 is set to
Auto
and accumulation is enabled. The display will indicate
AOut followed by a
Y
for enable or an
n
for disable. Press
OVER/UNDER/NEXT
,
UNITS
or
TARE
to change the selection. Press
PROGRAM/ENTER
to enter the selection.
bEEP:
Audible tone when key is pressed: This will enable or disable the audible
tone to acknowledge pressing a front panel key. The display will indicate
bEEP
followed by a Y for enable or an
n
for disable. Press
OVER/UNDER/NEXT
,
UNITS
or
TARE
to change the selection. Press
PROGRAM/ENTER
to enter
the selection.
C-FACt:
Conversion factor for custom units: The primary units divided by this
value will determine the custom units if it is enabled. The display will indicate
C-
FACt
followed by a value with the left digit flashing. Press
UNITS
to increase the
digit, press the
1
key to decrease the flashing digit. Press
OVER/UNDER/NEXT
to move the flashing digit to the right or press the
TARE
to move it to the left. Press
to move the decimal point to the right. Press
PROGRAM/ENTER
when
the display shows the correct conversion factor.
The default conversion factor is
8.3333
for gallons of water conversion.
Note: An example of custom units might be to display the weight in tons. In this case
the conversion factor is 2000.0 if the primary unit is lb.
The NexWeigh instrument will now return to the
APP
prompt. Navigate to the
desired menu heading to continue programming, or to
Done
if finished.