Section 5: Serial I/O

04/14

49

51216 -- Rev. 6

5.4.8. NexWeigh Serial Commands and Definitions,

Continued

k)

Recall Settings

Definition: Use recall current settings for Program, IO, and Checkweigh.
Recommended to not use if output mode is continous, as data will begin to be
overwritten with weight data.

Command: ‘rcs’ ‘category’

Options:

I, P, C

Sample Command: "rcs P\r"

l)

Change Active recipe

Definition: Used to change to a particular recipe setting. Simulates the pressing of
one of the recipe keys, only performed if that recipe is enabled.

Command: ‘rcp’ ‘recipe’

Options:

1,2,3,4,0

Sample Command: "rcp 1\r"

m)

Autotare Weight

Definition: Used to Autotare the gross weight. Simulates the pressing of Auto tare
key. Only performed if motion criteria and Atare Enable met.

Command: ‘A’

Options:

none

Sample Command: "A \r"

n)

Set Balance Band

Definition: Used to set the balance (motion) band. Only valid settings allowed.

Command: ‘SBB’ ‘divisions’

Options:

0.5, 1, 3, 0

Sample Command: "SBB 0.5\r"

Sample Command: "SBB 3\r"

o)

Set Display Rate

Definition: Used to set display update rate time in mSec. Only valid settings allowed.

Command: ‘SDR’ ‘mSec’

Options:

100, 200, 500, 800, 1000 etc.

Sample Command: "SDR 500\r"

Sample Command: "SDR 1000\r"