WIRING
i-Series intercom panels use a twisted 4-pair transmission scheme to
connect them to the matrix frame using the industry standard RJ-45
connector. Refer to Installing an Eclipse Matrix System: An Overview
for connector installation and use, and the type of cable needed for
connection between panels and frames.
Each pair of the twisted 4-pair wire has the following function:
• Pair 1 transmits analog audio from the matrix port to the panel.
• Pair 2 transmits digital data from the panel back to the matrix card
port.
• Pair 3 transmits audio from the panel to the matrix card port.
• Pair 4 transmits digital data from the matrix port back to the panel.
Figure 6-1: Matrix Frame to Panel Wiring
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
Matrix Frame End
Pair 2
Pair 1
Pair 3
Pair 4
ATT-T568B (Modular Jumpers Wired One to One)
1 2 3 4 5 6 7 8
Rear View of
Connector
RS-422 Receive +
RS-422 Receive -
Audio Receive +
Audio Send +
Audio Send -
Audio Receive -
RS-422 Send +
RS-422 Send -
Panel End