RUN Pass/Fail test, please follow the steps below:
1. Press UTILITY button to enter the “Utility menu”.
2. Press the “Next Page Page1/4” option button.
1. Press the “Next Page Page2/4” option button to enter the third
page of “Utility menu”.
2. Press the “Pass/Fail” option button to enter the “Pass/Fail”
function menu.
3. Press the “Enable Test” option button to select “On”.
4. Press the “Source” option button to select input signal channel.
5. Press the “Next Page Page1/2”option button to enter the second
page of the “Pass/Fail menu”.
6. Press the “Mask Setting” option button to enter the first page of
the “Mask menu”.
7. Press the “X Mask” button; turn the “Universal” knob to adjust the
horizontal clearance.
8. Press the “Y Mask” button; turn the “Universal” knob to adjust the
vertical clearance.
9. Press the “Create Mask” button to create mask and you can also
enter the next page of “Mask menu” to recall the stored mask.
10. Enter the second page of “Pass/Fail function menu”, press the
“Output” option button to set the output option.
11. Enter the first page of “Pass/Fail function menu”, press the
“Operate” option button to select “
”to run the pass/fail test.
Waveform Recorder
Press the Record option to record the input waveform from CH1, CH2,
CH3, or CH4 with a maximum record length of 2500 frames. The time
between frames is adjustable. You can record Pass/Fail test output
(especially useful when capturing abnormal signals over a long period of
time) without having to watch the signal.
Table 59 - Waveform Recorder Function Menu
Option
Setting
Description