beautypg.com

0 start up and verification, continued – Alpha Technologies AlphaNet IDH4 for XM3-HP Series - Technical Manual User Manual

Page 74

background image

74

746-257-B5-001, Rev. A1 (11/2013)

9.3.1 Detailed LED Descriptions, continued

REG - CM Registration
This LED blinks while the modem registers with the DHCP and obtains the configuration file after

downstream channel CM/CMTS negotiation. Once the registration is complete, the LED will display solid

GREEN. This indicates that the IDH4 Series is communicating with the CMTS in the headend.
DS - Downstream Communication
The LED flashes while searching for the downstream DOCSIS channel and is on solid when the

downstream channel is locked. This LED indicates CM downstream signal status. This process may

take several seconds, depending on how long it takes the CM to locate a carrier signal and lock onto a

channel.
ACT - CPE Activity
The CPE activity LED flashes to indicate that data is being transmitted or received between the IDH4

Series and a network device.
LNK - Network Communication Status
The Ethernet link LED remains ON when there is an active connection on the Ethernet port (e.g., a

computer is connected for local diagnostics).
Rx/Tx Power
The Rx/Tx PWR LED tricolor LED provides the quick verification of the modem transmit (Tx) and receive

(Rx) RF power levels. The Rx/Tx PWR LED is GREEN when both the cable modem Tx and cable

modem Rx RF power levels are within the range as specified in

Table 9-1, SCTE-HMS Property Table.

It is BLUE when Rx and/or Tx levels are within the “warning” range as specified by the SCTE-HMS

PropertyTable. The LED is RED when Rx and/or Tx levels are outside the range as specified by the

SCTE-HMS PropertyTable.

9.0 Start Up and Verification, continued

Parameter

alarm Enable HiHi

Hi

Lo

LoLo Deadband

Rx

docsIfDownChannelPower

(OID:1.3.6.1.2.1.10.127.1.1.1.1.6)

00

(0F*)

150

100

-100

-150

15

Tx

docsIfCmStatusTxPower

(OID:1.3.6.1.2.1.10.127.1.2.2.1.3)

00

(0C*)

550

500

00

00

15

*Values in ( ) denote behavior of the Rx/TX LED if alarmEnable bits are set to ‘00’.

By default, alarmEnable is set to 00 (disabled) to prevent unwanted SNMP traps but the LED behavior will

function as if the alarmEnable were set to the values in the SCTE-HMS Property Table. If the alarmEnable

bits are set to anything other than 00 the LEDs will then follow the behavior of the desired enable bit

setting.
The SCTE-HMS Property Table values translate into the following Rx/Tx Power LED color ranges:

LED Color

Rx Range (dBmV)

Tx Range (dBmV)

Green

+10 to -10

0 to +50

Blue

+15 to +10 and -10 to -15

+50 to +55

Red

>+15 and <-15

>+55

In addition to the above SCTE-HMS PropertyTable entries, the Tx and Rx levels displayed on the IDH4

Series Web page will each provide colored indicator bars that correlate to the RF LED and SCTE-HMS

PropertyTable thresholds.

Table 9-1, SCTE-HMS Property Table

Table 9-2, Rx/Tx Power LED Color Ranges