Fig. 7-8, System Interconnection Diagram

7.7

Front Panel Connections

Connections

Connections with more

than one power supply

Battery Sense Wire Harness

Refer to Section 8.0 Battery Sense Wire

Kits for part numbers and wiring options.

C

O

M

S

Y

S

C

O

M

S

Y

S

Generator (ECM)

ECM to SCM Interface

(Alpha P/N 704-709-20)

B

C

A

A

B

Comm Port

System Port

Battery Sense Connections

B

C

A

A

Environmental connection
Ethernet connection

RF connection

7.0 Installation, continued

Connect the RF drop according to the diagram below. The RF drop must have a properly installed ground

block in the power supply enclosure. Recommended downstream RF level is 0 dBmV. Connect any other

front panel connections at this time (e.g. battery strings, tamper switch).

Install a grounded surge suppressor (Alpha P/N 162-028-10 or equivalent) to protect

equipment from overvoltage.

CAUTION!

RF Cable

to Headend

Grounded Surge Protector

(See Caution Above)

Fig. 7-7, Connecting the RF Drop

7.6

Connecting the RF Drop

Linked CableUPS

Serial Interface Cards

IDH4 Series in

Primary XM3-HP

AlphaBus Cable

(Alpha P/N 875-190-20 for 6',

-21 for 9', -22 for 18', -23 for 35')