Table 124, At8xc51snd1c – Rainbow Electronics AT89C51SND1C User Manual
Page 139

139
AT8xC51SND1C
4109E–8051–06/03
Notes:
1. These frequencies are achieved in X1 mode, F
PER
= F
OSC
÷
2.
2. These frequencies are achieved in X2 mode, F
PER
= F
OSC
.
Baud Rate Selection (Mode 2)
In mode 2, the baud rate can only be programmed to 2 fixed values: 1/16 or 1/32 of the
peripheral clock frequency.
As shown in Figure 107 the selection is done using SMOD1 bit in PCON register.
Figure 108 gives the baud rate calculation formula depending on the selection.
Figure 107. Baud Rate Generator Selection (Mode 2)
Table 124. Internal Baud Rate Generator Value
Baud Rate
F
PER
= 6 MHz
(1)
F
PER
= 8 MHz
(1)
F
PER
= 10 MHz
(1)
SPD
SMOD1
BRL
Error %
SPD
SMOD1
BRL
Error %
SPD
SMOD1
BRL
Error %
115200
-
-
-
-
-
-
-
-
-
-
-
-
57600
-
-
-
-
1
1
247
3.55
1
1
245
1.36
38400
1
1
246
2.34
1
1
243
0.16
1
1
240
1.73
19200
1
1
236
2.34
1
1
230
0.16
1
1
223
1.36
9600
1
1
217
0.16
1
1
204
0.16
1
1
191
0.16
4800
1
1
178
0.16
1
1
152
0.16
1
1
126
0.16
Baud Rate
F
PER
= 12 MHz
(2)
F
PER
= 16 MHz
(2)
F
PER
= 20 MHz
(2)
SPD
SMOD1
BRL
Error %
SPD
SMOD1
BRL
Error %
SPD
SMOD1
BRL
Error %
115200
-
-
-
-
1
1
247
3.55
1
1
245
1.36
57600
1
1
243
0.16
1
1
239
2.12
1
1
234
1.36
38400
1
1
236
2.34
1
1
230
0.16
1
1
223
1.36
19200
1
1
217
0.16
1
1
204
0.16
1
1
191
0.16
9600
1
1
178
0.16
1
1
152
0.16
1
1
126
0.16
4800
1
1
100
0.16
1
1
48
0.16
1
0
126
0.16
0
1
SMOD1
PCON.7
PER
CLOCK
ч
2
ч
16
To Serial Port