Internal Baud Rate Generator

When using the Internal Baud Rate Generator, the Baud Rate is derived from the over-
flow of the timer. As shown in Figure 95 the Internal Baud Rate Generator is an 8-bit
auto-reload timer fed by the peripheral clock or by the peripheral clock divided by 6
depending on the SPD bit in BDRCON register (see Table 129). The Internal Baud Rate
Generator is enabled by setting BBR bit in BDRCON register. SMOD1 bit in PCON reg-
ister allows doubling of the generated baud rate.

Figure 95. Internal Baud Rate Generator Block Diagram

Synchronous Mode
(Mode 0)

Mode 0 is a half-duplex, synchronous mode, which is commonly used to expand the I/0
capabilities of a device with shift registers. The transmit data (TXD) pin outputs a set of
eight clock pulses while the receive data (RXD) pin transmits or receives a Byte of data.
The 8-bit data are transmitted and received least-significant bit (LSB) first. Shifts occur
at a fixed Baud Rate (see Section "Baud Rate Selection (Mode 0)", page 136).
Figure 96 shows the serial port block diagram in Mode 0.

Figure 96. Serial I/O Port Block Diagram (Mode 0)

Transmission (Mode 0)

To start a transmission mode 0, write to SCON register clearing bits SM0, SM1.

As shown in Figure 97, writing the Byte to transmit to SBUF register starts the transmis-
sion. Hardware shifts the LSB (D0) onto the RXD pin during the first clock cycle
composed of a high level then low level signal on TXD. During the eighth clock cycle the
MSB (D7) is on the RXD pin. Then, hardware drives the RXD pin high and asserts TI to
indicate the end of the transmission.

0

1

Overflow

SPD

BDRCON.1

BRG

(8 bits)

BRL

(8 bits)

PER

CLOCK

÷

6

IBRG

CLOCK

BRR

BDRCON.4

0

1

SMOD1

PCON.7

÷

2

To serial
Port

BRG

CLOCK

TXD

RXD

SBUF Tx SR

SBUF Rx SR

SM1

SCON.6

SM0

SCON.7

Mode Decoder

M3 M2 M1 M0

Mode

Controller

RI

SCON.0

TI

SCON.1

PER

CLOCK

Baud Rate

Controller