2 wildcard subscription, 4 deleting pps, 5 searching within the pp list – AASTRA SIP-DECT (Release 3.0)- OM System Manual - Installation, Administration and Maintenance EN User Manual
Page 78: Wildcard subscription, Deleting pps, Searching within the pp list

SIP–DECT OM System Manual Release 3.0
7 OMM Web Service
Aastra
depl-1624/1.0
Page: 78 (241)
The OMM will allow a subscription of configured but not subscribed PPs during the next24
hours. The administrator must press the Subscribe button again to permit more PP handsets
to subscribe to the SIP–DECT system.
Note:
Some older PPs may not offer the possibility to enter an access code (AC). You
should always subscribe these devices with configured IPEI to maintain security.
7.7.3.2 Wildcard Subscription
To minimize administration effort, subscription is also possible, if the IPEI is not configured.
But because of the loss of further security by IPEI check, this kind of subscription is only
allowed within a short default time interval of 2 minutes.
To enable subscriptions, press the
Start
button of the section
Wildcard subscription
on the
Portable parts
page. If necessary, increase the time interval (or refresh subscription
permission in time).
The OMM will allow a wildcard subscription during the set time interval. In case of timeout the
permission is lost. Only subscription with IPEI remains allowed within the fixed limit of 24
hours (see chapter7.7.3.1).
To achieve a selection of data during subscription (e.g. the user name being assigned to the
PP), the field “additional ID” can be set in OMM data. If the OMM receives a valid “additional
ID” during subscription, the referring data are assigned to the PP.
If the additional ID is requested for a data record, the PP user has to type it. “Additional ID”
can be set within the authentication code menu. Please type the R-Key and type the
additional ID.
Please note:
The input of the additional ID is only possible with Aastra DECT 142 / Aastra
142d and Aastra 600d / 650c. There is no possibility to type that value on third
party GAP phones. If GAP phones are going to subscribe wildcard, the first
free PP data record without any additional ID will be selected and assigned.
7.7.4
Deleting PPs
To delete an existing RFP:
1 On the
Portable parts
page click on the
icon left behind the PP entry.
The
Delete portable part?
dialog opens showing the current configuration of this PP.
2 Press the
Delete
button.
7.7.5
Searching within the PP List
To search for a certain handset in the PP list, the search function can be used which allows
to find a handset by a given number or IPEI.
1 On the
Portable parts
page click on the
Search
button.
The
Search portable parts
dialog opens.