2 rfp configuration file / central (omm database), 1 supported instructions, Rfp configuration file / central (omm database) – AASTRA SIP-DECT (Release 3.0)- OM System Manual - Installation, Administration and Maintenance EN User Manual
Page 227: Supported instructions

SIP–DECT OM System Manual Release 3.0
11 Appendix
Aastra
depl-1624/1.0
Page: 227 (241)
Parse log about import / instruction processing
 OK: start_number = 5401 
 OK: ac = 1001 
 OK: additional_pin = number 
 OK: sip_user = number 
 OK: sip_pw = number 
 OK: sos_number = 5002 
 OK: mandown_number = 5002 
 
 OK: no_of_number = 10 
 
 Section processing: 
 
[…] 
11.7.2
RFP Configuration File / Central (OMM Database)
Import of RFP configurations using files is possible with Web Service or OMM Management 
portal. 
11.7.2.1 Supported Instructions
All instructions are taken as common value which are set to all records of data sequence 
section of that file if the corresponding field is empty. 
Instruction
Explanation
active
Activation of DECT: {‘0’ or ‘false ’= inactive, ‘1’ or ‘true’ = active }
cluster
Cluster, the RFP is referred to - RFP-OMM: {1..256}, PC-OMM: {1..2048}
paging_area
Paging area, the RFP is referred to: {‘unassigned, ’0’..’127’} 
Ignored by WEB import and always set to ‘0’ (Paging area 0) 
sync_source
Synchronization source: {‘0’ or ‘false ’= inactive, ‘1’ or ‘true’ = active }
refl_env
Reflective environment: {‘0’ or ‘false ’= no, ‘1’ or ‘true’ = yes }
site
Site Id: {1..250}
wlan_profile
Reference key to an existing WLAN profile
wlan_antenna
Antenna settings: {0=diversity, 1, 2}
wlan_channel_bg WLAN channel: {0..14 (size depends on regulatory domain) }
wlan_power
WLAN power: {6, 12, 25, 50,100 (in percent)}
wlan_act
Activation of WLAN: {‘0’ or ‘false ’= inactive, ‘1’ or ‘true’ = active }
Note:
Web import allows currently only ‘0’ or ‘1’ for Boolean parameters.