The RFP will retry to get the configuration files, starting with an interval of 1 minute and 
doubling this interval with each retry, not exceeding the update check interval (either 
default or configured). 
•
If the RFP is using DHCP, a renew of the lease is scheduled so that possible changes in 
DHCP configuration will be detected. 
•
Failures in getting the configuration files is reported via Syslog.
Handling of parameter changes
A change of a parameter (DHCP / OM Configurator, RFP config files) does not necessarily 
mean a change of the RFP configuration because the parameter could be covered up or 
previously set by using an alternative way. 
Example 1: 
IP address of a Syslog Daemon has been changed in “ipdect.cfg” but is covered up by 
“
Example 2: 
A parameter is new in “
same parameter value. 
Only if a parameter change causes a change of RFP configuration as a sum of e.g. DHCP / 
OM Configurator, “ipdect.cfg” and “
update procedure. 
Depending on the changed parameter an RFP configuration update is done:
•
On the fly without any service interruption e.g. IP address of a Syslog Daemon has been 
changed. 
•
With an application restart e.g. OMM IP address has been changed.
Configuration file syntax
############################################################################## 
# sample configuration file for the OpenMobility system 
# retrieved via the net using file transfer protocols like tftp, ftp or http 
# 
# Insert the URL to the folder containing this file into DHCP option 66 
# (TFTP Server) or use the OM Configurator parameter "configuration file 
# server" 
# Insert a URL e.g. ftp://server/path/ (http, https, tftp, ftp, ftps) 
############################################################################## 
# comments are starting with the hash sign: "#" 
# 
##############################################################################
## 
# BOOL variables support the following values 
# YES Y 1 TRUE (case does not matter) 
# NO N 0 FALSE (case does not matter) 
# other values are interpreted as false 
# 
############################################################################## 
# configuration files check interval 
# 
# time interval for checking the remote cfg files in seconds 
# minimum value is 300 (5 minutes) 
# maximum value is 604800 (7 days) 
OM_ConfigCheckInterval=300 
############################################################################## 
# personal configuration files 
# 
# personal configuration files have the following name 
# 