8.9.3.1 Creating “Alarm triggers”
In configuration mode you can create new alarm triggers.
1 Click
Create
. In the
General
tab enter the alarm trigger parameters.
2
Trigger ID
: Enter the Trigger ID. The Trigger ID identifies the alarm scenario and also
selects the source which triggers the alarm.
3
Feature access code
: Enter the access code which should be assigned to the alarm
trigger.
4
Comment
: Enter a comment for the new trigger.
5
Prefix
: This field displays the
FAC number
which introduces the feature access code
(see also chapter 8.9.1).
6
Number
: Enter the number to be called in case of this alarm trigger.
7 Press the
OK
button.
8.9.3.2 Configuring “Alarm triggers”
In configuration mode you can configure an existing alarm trigger.
1 In the alarm trigger table click on the appropriate trigger entry.
2 Click
Configure
.
The
General
tab is displayed showing the current trigger configuration.
3 Change the trigger parameters, see chapter 8.9.3.1.
4 Press the
OK
button.
8.9.3.3 Deleting “Alarm triggers”
In configuration mode you can delete alarm triggers. The predefined alarm triggers (‘SOS
and ’Man down‘) can not be deleted.
1 In the alarm trigger table click on one or more trigger entries.
2 Click
Delete
.
3 Confirm the displayed prompt with
OK
.