2 Configure the PP, see parameter description below.
3 Press the
OK
button.
The following parameters can be set in the
New portable part
resp. the
Configure portable
part
dialog:
General settings
•
Name
: The name parameter represents the SIP Display Name field. This parameter is
optional but recommended.
•
Number
: The number is the SIP account number or extension for the PP.
•
IPEI
: This optional setting is the DECT handset IPEI number. On an Aastra DECT 142 /
Aastra 142d handset, the IPEI can be found via the following path of the device menu:
Main menu
>
Phone settings
>
System
. On an Aastra 600d / 650c handset, the IPEI
can be found in the
System
device menu. Consult the handset’s user guide for further
information.
•
DECT authentication code
: The DECT authentication code is used during initial DECT
subscription as an security option and can be set here for each PP separately (handset-
specific DECT authentication code). This parameter is optional. If a system-wide DECT
authentication code is given on the
System settings
page (see chapter 7.4.1), this value
is filled in here as default. If no handset-specific DECT authentication code is set, the
system-wide DECT authentication code is used.
Note:
The DECT authentication code can only be changed if the PP is not subscribed.
•
Login/Additional ID
: The additional ID can be used as a mean for data search within
wildcard subscription (because of the IPEI is not configured which selects the data
otherwise).
•
Delete subscription
: This option is only available when configuring an existing PP (in the
Configure portable part
dialog). If this option is selected, the PP will be unsubscribed.
•
SOS number
,
ManDown number
: SOS and ManDown are calling numbers which will be
automatically called as soon as an SOS or ManDown event happens. If no individual SOS
or ManDown number is configured for a handset, the number of the appropriate alarm
trigger will be used as a system-wide calling number in case of a SOS or ManDown event.
Please see chapter 8.9.3 and /28/ for details.
•
Voice mail number
: The voice mail number is the number which will be automatically
called as soon as a voice mail call is initiated on the Aastra 600d / Aastra 650c handset. If
there is no individual voice mail number configured in this field, then the system-wide
voice mail number is used (see also the
System setting
menu, chapter 7.4.1). If there is
no voice mail number configured (neither the individual nor the system-wide) or another
handset type is used, then the voice mail number must be configured locally in the
handset.
SIP authentication
•
User name
: The SIP Authentication user name is optional but recommended. It
represents the name which will be used during SIP registration and authentication. If no
name is given the number will be used by default.
•
Password
,
Password confirmation
: The password will be used during SIP registration
and authentication. Enter the appropriate data in these fields.