7 OMM Web Service
Aastra
depl-1624/1.0
Page: 76 (241)
4 Select the PPs you want to add to the OMM database by selecting the appropriate
checkboxes.
5 Press
Add
.
All successfully stored records are marked green in the
Added
column.
Failed records are marked with a red star.
6 To read error hints in the referring log file, press the
Log file
button. Error hints can also
be read in a syslog trace (see chapter 7.4.1).
7 To remove imported data entries, activate the check box next to the desired entries. Press
Delete
to remove the selected entries.
7.7.3
Subscribing PPs
Preparation by OMM Web service
After adding a PP configuration to the OMM, the PP must be subscribed. The OMM must first
be enabled to allow subscriptions to be take place from PP handsets. This is done by
pressing the following buttons on the Portable Parts OMM web page.
•
Start
button of the
Subscription with configured IPEIs
section (see chapter 7.7.3.1).
This button enables the subscription for the next 24 hours.
or
•
Start
button and time interval of the
Wildcard Subscription
section (see chapter Note:).
This button enables the “wildcard subscription” for the selected time. After expiry the