Page 24

SIP–DECT OM System Manual Release 3.0
2 Getting Started
Aastra
depl-1624/1.0
Page: 24 (241)
Note:
The RFP L35 IP / RFP L36 IP / RFP L37 IP / RFP L43 WLAN and RFP L32 IP /
RFP L34 IP / RFP L42 WLAN devices provide a built-in license as described here. If
you have purchased another license type, you need to upload the license file on the
Licenses
page now (see chapter6).
5 Navigate to the
Radio fixed parts
page. Click the
Start
button to start capturing. Wait 10
seconds. Click the
Radio fixed parts
menu entry to refresh the display. If all expected
RFPs are listed, click
Stop
to end capturing.
Radio fixed parts, capture and add new RFPs
6 Click the
icon next to the desired entry to add a new RFP to the OMM. The
New radio
fixed part
dialog opens. Enter a
Name
. Enable the
DECT settings
checkbox that assigns
the RFP to
DECT cluster
“1”. Confirm with
OK
. Repeat this step for the second RFP.
7 Navigate to the
Portable parts
page. Click on the
New
button. The
New portable part
dialog opens. Enter a
Name
, a
Number
and a
DECT authentication code
. Confirm with
OK
. Repeat this step for a second DECT portable part with a different
DECT
authentication code
.