Quantum Data 802BT User Manual
Page 81

802BT/802R Video Test Generator User Guide
71
The following table describe the default DCS priority scheme for horizontal sync.
The following table describe the default DCS priority scheme for vertical sync.
To enable the legacy DCS priority scheme:
1. Turn off the generator.
2. Hold down the
Step
and
DCS
keys while starting the generator.
The generator will remain in this mode through subsequent power cycles until the
generator is re-initialized or reset with the “No special modes” command (hold down
ACS+DCS+DSS while starting the generator).
OUTG
SSST
HSPG
HS Output
HS Polarity
0
Do not care
Do not care
No signal
Do not care
1
Do not care
0
No signal
Do not care
Do not care
8 (DPMS – OFF)
Do not care
No signal
Do not care
1
9 (DPMS – SUS-
PEND)
Do not care
Horizontal Sync
HSPP
1
10 (DPMS –
STANDBY)
Do not care
No signal
Do not care
1
1, 3, 5, 7, or 11
1
Horizontal Sync
HSPP
1
2, 6, or 11 (DCS)
1
Composite Sync
CSPP
OUTG
SSST
VSPG
VS Output
VS Polarity
0
Do not care
Do not care
No signal
Do not care
1
Do not care
0
No signal
Do not care
Do not care
8 (DPMS – OFF)
Do not care
No signal
Do not care
1
9 (DPMS – SUS-
PEND)
Do not care
No signal
Do not care
1
10 (DPMS –
STANDBY)
Do not care
vertical Sync
VSPP
1
1, 3, 5, 7, or 11
1
vertical Sync
VSPP
1
2, 6, or 11 (DCS)
1
Composite Sync
CSPP