Appendix C
Error Messages
2130
Horizontal active too small
The number of active pixels per horizontal scan line is less than the minimum supported
by the generator hardware configuration.
2140
Horizontal blanking too small
The video format’s horizontal blanking period expressed in microseconds and/or number
of pixel clock cycles is not supported by the generator hardware configuration.
2141
Horizontal blanking too small
Same as Error number 2140. Found in some firmware releases for different generator
hardware configurations.
2150
Horizontal blanking too small
Same as Error number 2140. Found in some firmware releases for different generator
hardware configurations.
2151
Horizontal total less than horizontal resolution
The video format’s total (active + blanked) number of pixel clock cycles per horizontal scan
line can not be less than the number of active pixels per scan line.
2152
Horizontal resolution too large or Horizontal blanking too small
Same as Error number 2140. Found in some firmware releases for different generator
hardware configurations.
2155
Horizontal blanking too small
Same as Error number 2140. Found in some firmware releases for different generator
hardware configurations.
2180
Horizontal pulse width too small
The generator hardware configuration does not support video formats having horizontal
sync pulse widths less than one pixel clock cycle long.
2181
Horizontal sync pulse width not even
Number of pixel clock cycles in the horizontal sync pulse width must be evenly divisible by
2 at the current pixel clock rate for the video format and generator hardware configuration.
2190
HSPW too small for HDTV sync
The generator hardware configuration does not support video formats having horizontal
sync pulse widths less than two pixel clock cycles long for the current video and HDTV
sync type selections.