Quantum Data 802BT User Manual
Page 740

730
Appendix C
Error Messages
9500
I2C stream too big
There was a communications error within the generator hardware architecture because
the data stream size exceeded the size supported by the device.
9500
Sequence data not found
An attempt was made to use the SEQR command to read a sequence from an empty
sequence storage location.
9501
I2C data missing
There was a communications error within the generator hardware architecture because
the device data stream was missing.
9502
I2C register missing
There was a communications error within the generator hardware architecture.
9503
I2C data byte missing
There was a communications error within the generator hardware architecture because
the device data stream had missing data.
9504
Serial digital video PLL not locked
There is an internal problem with the generator’s serial digital video hardware’s Phase
Lock Loop circuit.
9505
TV output hardware not ready
The generator’s serial digital video generating hardware is not yet ready to output video
9506
Serial digital video hardware not ready
The generator’s TV signal generating hardware reports it is not yet ready to output valid
video
9507
I2C offset missing
There was a communications error within the generator hardware architecture
9508
Invalid HDCP receiver KSV
The HDCP Key Selection Vector returned from the HDCP receiver in the Unit Under Test
(UUT) is not valid.
9520
HDCP key combination not supported
The HDCP key combination between the Tx and the Rx is invalid. The Tx may have
production keys and the Rx public keys.
9521
HDCP failed after a while
The HDCP authentication started but failed after a while.