Pngu, Pngu pseudo noise generator use – Quantum Data 802BT User Manual
Page 485

Video Test Generator User Guide
475
PNGU
Pseudo Noise Generator Use
Class
Signal Analyzer - Pseudo-random noise
Description
Loads the hardware required to generate pseudo-random noise (per the latest
pseudo-random noise signal settings).
Command syntax
PNGU
Example 1
PNSF 1 //Pseudo-random noise signal format set to CURRENT (internal)
PNST 1 //Pseudo-random noise signal type set to QDI-BCM
PNSA 1 //Pseudo-random noise signal advance set to ACTIVE PIXELS
PNSM 0 //Pseudo-random noise signal mode set to AUTO
PNSP 0 //Pseudo-random noise signal procedure set to CONTINUOUS
PNSG 1 //Pseudo-random noise signal gate set to ON
PNGU //Output Pseudo-random noise using latest parameters
Example 2
To stop pseudo-random noise output:
PNSG 0 //Pseudo-random noise signal gate set to OFF
PNGU
Related commands