Equa – Quantum Data 802BT User Manual
Page 321

Video Test Generator User Guide
311
EQUA
EQUalization interval After vertical sync pulse
Class
Format parameter setting - synchronization
Description
Establishes the width of the equalization interval after the vertical sync pulse in each field
whenever a serrated and equalized sync type is selected via either
or
commands and selected via the
command. If the type specified for the selected
sync signal is one of the CCIR types, then the actual equalization interval output by the
generator will be 0.5 lines shorter than the whole number specified. The EQUA? query
returns the current setting of EQUA.
Command syntax
EQUA lines
lines
min = 0
max = number of lines after vertical sync before video
Query syntax
EQUA?
Query response
lines
Other required
commands
The
command instructs the generator to use the new setting. The
command
updates hardware to the new setting and redraws the test image.
Example
EQUA 3 // Set post-equalization to 3 lines in buffer
FMTU
// Update hardware to current buffer contents