Asss, Asss analog sync signal swing – Quantum Data 802BT User Manual
Page 247
Video Test Generator User Guide
237
ASSS
Analog Sync Signal Swing
Class
Format parameter setting - Analog video signal
Description
Sets the maximum peak-to-peak swing for any composite sync that is added to any of the
three analog video channels. The actual peak-to-peak swing of the analog sync signals at
the output connectors equals the product of ASSS multiplied by ASSC. The ASSS? query
returns the current setting of ASSS.
Command syntax
ASSS level
level
min = 0.000 volts (floating point accepted)
max = 0.400 volts (floating point accepted)
Query syntax
ASSS?
Query response
level
Other required
commands
modes must be set to ON and the
type must be 4, 5, 6 or 7 to
output analog sync. The
command instructs the generator to use the new setting.
The
command updates hardware to the new setting and redraws the test image.
Example
ASSS 0.286 // Set sync swing to 286 mV in buffer
FMTU