Hspg, Hspg horizontal sync pulse gate – Quantum Data 802BT User Manual
Page 381

Video Test Generator User Guide
371
HSPG
Horizontal Sync Pulse Gate
Class
Format parameter setting - Synchronization
Description
Enables and disables the digital horizontal sync output. The HSPG? query returns the
current HSPG mode.
Command syntax
HSPG mode
mode
0 = OFF
1 = ON
Query syntax
HSPG?
Query response
0 or 1
Other required
commands
To use digital horizontal sync, digital separate H and V sync must be selected with the
command. The
command instructs the generator to use the new settings.
The
command updates the hardware to the new settings and redraws the test
image.
Example
HSPG 1 // Enable H sync output in buffer
FMTU
// Update hardware to current buffer contents
This manual is related to the following products: