Sxex, Sxex signal-from-extended aperture map – Quantum Data 802BT User Manual
Page 553

Video Test Generator User Guide
543
SXEX
Signal-From-Extended Aperture Map
Class
Format parameter setting - HDMI active video
Description
Maps EXAR-shaped image content into the SXAR-shaped signal interface.
Command syntax
SXEX code
code
0 to 131071 (in decimal)
The mapping code is made up of three binary field codes as follows:
•
Bits 0-2 are the Squeeze/Stretch (“S”) field code
•
Bits 3-9 are the Letterbox/Pillar (“L”) field code
•
Bits 10-16 are the Safe Area (“K”) field code
Note: For help in determining the proper mapping code, follow the procedure on page 318
(
command).
Related commands
,
,
Example
SXEX 264 //Use centered shrink w/black bars top & bottom
FMTU