372
Appendix A Command Reference
HSPP
Horizontal Sync Pulse Polarity
Class
Format parameter setting - Synchronization
Description
Establishes the logic sense of the digital horizontal sync outputs. Setting polarity to 1
causes the leading edge of horizontal sync to be a low-to-high transition. Setting polarity to
0 causes the leading edge of horizontal sync to be a high-to-low transition. The HSPP?
query returns the current polarity of HSPP.
Command syntax
HSPP polarity
polarity
0 = active-low (negative going pulse)
1 = active-high (positive going pulse)
Query syntax
HSPP?
Query response
0 or 1
Other required
commands
To use digital horizontal sync, it must be gated on with the
command and digital
separate H and V sync must be selected with the
command. The
command
instructs the generator to use the new settings. The
command updates the
hardware to the new settings and redraws the test image.
Example
HSPP 0 // Set active low H sync in buffer
HSPG 1 // Enable H sync output in buffer
SSST 1 // Select H&V sync type in buffer
FMTU