VSPG
Vertical Sync Pulse Gate
Class
Format parameter setting - Synchronization
Description
Enables and disables the digital vertical sync output. The VSPG? query returns the
current mode of VSPG.
Command syntax
VSPG mode
mode
0 = OFF
1 = ON
Query syntax
VSPG?
Query response
0 or 1
Other required
commands
To use digital vertical sync, digital separate H and V sync must be selected with the
command. The
command instructs the generator to use the new setting. The
command updates hardware to the new setting and redraws the test image.
Example
VSPG 1 // Enable V sync output in buffer
FMTU
// Update hardware to current buffer contents