Appendix A Command Reference

HVSA

Horizontal Vertical Sync Adjustment

Class

Format parameter setting - Synchronization

Description

Lengthens the serration period a given number of pixels from the format’s nominal default

value as required by certain military STANAG video formats. The HVSA? query returns the

current setting of HVSA.

Command syntax

HVSA pixels

pixels

integer, 0 and less than HSPW

Query syntax

HVSA?

Query response

pixels

Other required

commands

The

FMTU

command instructs the generator to use the new settings. The

ALLU

command

updates the hardware to the new settings and redraws the test image.

Example

HVSA 30;