Quantum Data 802BT User Manual
Page 739

802BT/802R Video Test Generator User Guide
729
9477
Error duplicating formats
The
9480
Format not found / Format data missing
The FMTR command tried to read a format from an empty format storage location.
9490
DDC mod not present
The generator hardware configuration does not support DDC communications.
9491
DDC not available
The generator hardware configuration does not support DDC communications.
9492
DDC2B no ACK from receiver
Low level DDC communications failed with Unit Under Test (UUT). No DDC
acknowledgment bit was received from the UUT.
9493
DDC2B arbitration lost
Low level DDC communications failed with Unit Under Test (UUT). DDC bus arbitration
lost with the UUT.
9494
DDC2B timeout on bus
Low level DDC communications failed with Unit Under Test (UUT). DDC communications
timed out with the UUT.
9496
EDID header not found
A valid block of header data could not be found in the EDID data read back from Unit
Under Test (UUT).
9497
DDC old monitor
A DDC compliant Unit Under Test (UUT) could not be found connected to the generator.
9498
I2C address missing
There was a communications error within the generator hardware architecture because
the device address was missing.
9499
I2C count missing
There was a communications error within the generator hardware architecture because
the data count was missing.