9522
HDCP key combination not supported
The HDCP authentication did not start.
9523
HDCP production keys not supported
HDCP test initiated and specified production keys where are not supported in generator
option.
9524
Invalid transmitter KSV
HDCP video transmitter KSV sent by the generator is invalid.
9525
HDCP Ri value not ready
HDCP authentication cannot start because HDCP Ri value (link verification response) at
the transmitter is not ready.
9527
HDCP Ri do not match
HDCP authentication cannot start because HDCP Ri (link verification response) values at
the transmitter and receiver do not match.
9528
HDCP was interrupted
HDCP authentication was interrupted possibly by disconnecting the cable.
9529
HDCP receiver not detected
HDCP authentication failed to start because the hot plug was not detected.
9530
HDCP invalid for animation
HDCP test will not run when an animated image is loaded.
9531
I2C segment number missing
The segment number of the enhanced DDC bus is missing.
9532
I2C address 1 missing
The first address of the enhanced DDC bus is missing.
9533
I2C address 2 missing
The second address of the enhanced DDC bus is missing.
9600
Can not save format to EPROM
An attempt was made to save a format edit buffer’s contents to a location in the firmware