Starting the analyzer – Quantum Data 802BT User Manual
Page 123

802BT/802R Video Test Generator User Guide
113
3. Using the
Image
knob, toggle between ON (to enable analyzer images) and OFF (to
disable analyzer images) setting.
4. Press and release the
Step
key to save the currently displayed parameters.
The light on the
Step
key extinguishes, and the new settings are implemented for
Analyzer mode operation.
Starting the analyzer
The analyzer functions as a special operating mode within the 802 generator. You must
place the generator into this mode to perform any analyzer tasks.
To put the generator in the analyzer mode:
1. Start the generator in Digital-Friendly mode (see page 18).
2. Press and release the Outputs key. The light on the key extinguishes.
3. While holding down the G key, press and release the Outputs key.
The Outputs key illuminates and the following message appears on the LCD. This
indicates that the generator is in analyzer mode (example shows DVI analyzer).
To take the generator out of the analyzer mode:
1. Press and release the Outputs key.
The generator is returned to the normal mode as a signal source. The LCD shows the
format and image currently active.