PUTR
PUT Relative
Class
Direct processor control
Description
Writes the specified value value into the location pointed to by the address register (see
the
command). The parameter value is interpreted according to the current setting
of BASE (see the
command). The number and format of the bits written depend on
the current setting of SIZE (see the
command). The address register is automatically
incremented by SIZE bits after the current location has been written to.
Note: This command is used only with custom applications and command files created by
Quantum Data. Indiscriminate use of this command can cause the generator to stop
operating and the loss of stored data in non-volatile RAM.
Command syntax
PUTR value
value
0 to (2^(SIZE))-1
Other required
commands
PUTR expects parameters formatted according to the current radix set by the