Quantum Data 802BT User Manual
Page 129

802BT/802R Video Test Generator User Guide
119
4. Using the
Format
knob, select the signal format you want to use.
Any built-in formats may be used for this test. However, we recommend using several
formats spread over a wide range of frequencies. For example, the Test165 format is
commonly used to test at the maximum pixel frequency (165 MHz), while the DMT0660
format can be used to test at a very low frequency (25.175 MHz).Use the following
formats to test single-link DVI over a range of frequencies:
5. Start the analyzer (see “
Starting the analyzer
” on page 113).
Format
Pixel rate (Mhz)
TEST165
165.000
DMT1660
162.000
DMT1285G
157.500
DMT1285A
148.500
DMT1648
135.000
DMT1275A
129.600
DMT1185
121.500
DMT1260G
108.000
DMT1085
94.500
DMT1170
94.200
DMT1075
78.750
DMT1070
75.000
720p60
74.250
DMT1060
65.000
DMT0885
56.250
DMT0872
50.000
DMT0875
49.500
DMT1043
44.900
DMT0860
40.000
DMT0685
36.000
DMT0785H
35.500
DMT0675
31.500
SMT0760V
28.322
DMT0660
25.175