Option Parameter

Description

Your

Setting

Boot
Monitoring
Policy

[Retry 3 Times]
Retry Service Boot
Always Retest

Appears when the boot monitoring feature is enabled. This
item indicates the processing at the occurrence of timeout
during boot monitoring.
If [Retry 3 times] is selected, the system is reset after the
occurrence of timeout and operating system boot is retried up
to three times. The failure in the third boot causes the boot to
be tried from the service partition.
If [Retry Service Boot] is selected, the system is reset after
the occurrence of timeout and operating system boot is
retried up to three times. Then the boot is tried from the
service partition for three times.
If [Always Reset] is selected, the system is reset after the
occurrence of timeout and operating system boot is retried
repeatedly.

Thermal
Sensor

Disabled
[Enabled]

Indicates whether the temperature sensor monitoring function
is enabled or disabled.

BMC IRQ

Disabled
[IRQ 11]

Indicates the IRQ of the BMC interrupt.

Post Error
Pause

Disabled
[Enabled]

Indicates whether POST is aborted once at the end of POST
if an error occurs during the execution of POST.

AC-LINK Stay

Off

[Last State]
Power On

Indicates the AC-LINK function. Shows the state of the power
of the server.

Power ON
Delay Time

[0] - 255

Sets the power on delay time when "Power On" or "Last
State" is specified for AC LINK.

FRU LED
Feature

Disabled
[Enabled]

Select "Enabled" to turn on the error lamp to identify the
location if the system detects a failure.

Clear FRU
LED

[No]
Yes

Select "Yes" to turn off the FRU LED. When the faulty
component is replaced, turn off the FRU LED.

Platform
Event
Filtering

Disabled
[Enabled]

Enables or disables the Platform Event Filtering feature of the
baseboard management controller (BMC).

[ ]: Factory-set

The table below shows the operation when the AC power to the server is turn off once and then on again, depending on
the setting of "AC-LINK."

Setting of AC-LINK

System status before AC power off

Stay Off

Last State

Power On

Operating Off

On

On

Aborting (DC power being off also)

Off

Off

On

Forced shutdown

Off

Off

On

* Press the power switch continuously at least four seconds. This forcibly turns off the power.

IMPORTANT:

Set this item to "Power on" in order to link the AC power source supplied

from UPS when the server is connected to UPS.