NEC 140He User Manual
Page 225

8-21
Error
code
Error message
Recommended Action
8171
Processor 2 not operating at intended
frequency
8172
Processor 3 not operating at intended
frequency
8173
Processor 4 not operating at intended
frequency
817F
All processors not operating at intended
frequency
Check the frequency of the processor. If it is unknown, contact
your service representative.
8200
Online Spare Memory was not ready.
DIMM type mismatch is detected when the online spare memory
feature is enabled.
Contact your service representative.
8201
Mirroring Memory was not ready.
DIMM type mismatch is detected or unnecessary installation in
group #2 is detected when the memory mirroring feature is
enabled. Check the DIMM type or installation. If the error cannot
be corrected, contact your service representative.
8202
Memory RAID was not ready.
Check if capacity, type, and installation status of all DIMMs are
correct.
8300
Secondary BIOS is corrupted.
Contact your service representative.