beautypg.com

NEC 140He User Manual

Page 223

background image

8-19

Error
code

Error message

Recommended Action

0B80 BMC

Memory

Test

Failed.

0B81

BMC Firmware Code Area CRC check failed.

0B82

BMC core hardware failure.

0B83

BMC IBF or OBF check failed.

0B8A

BMC SEL area full.

0B8B

BMC progress check timeout.

0B8C

BMC command access failed.

0B8D

Could not redirect the console - BMC Busy -

0B8E

Could not redirect the console - BMC Error -

0B8F

Could not redirect the console - BMC
Parameter Error -

0B90

BMC Platform Information Area corrupted.

0B91

BMC update firmware corrupted.

Turn off the power once and then on again to start the server. If
the error cannot be corrected, contact your service
representative.

0B92

Internal Use Area of BMC FRU corrupted.

All the commands and functions other than the FRU command
and the EMP function can be used. This is not a fatal error.
Turn off the power once and then on again to restart the server.
If the error cannot be corrected, contact your service
representative.

0B93

BMC SDR Repository empty.

Turn off the power once and then on again to restart the server.
If the error cannot be corrected, contact your service
representative.

0B94

IPMB signal lines do not respond.

All the functions other than the function of accessing to SMC
through IPMB can be used. This is not a fatal error. Turn off the
power once and then on again to restart the server. If the error
cannot be corrected, contact your service representative.

0B95

BMC FRU device failure.

All the commands and functions other than the FRU command
and the EMP function can be used. This is not a fatal error.
Turn off the power once and then on again to restart the server.
If the error cannot be corrected, contact your service
representative.

0B96

BMC SDR Repository failure.

0B97

BMC SEL device failure.

0B98

BMC RAM test error.

0B99

BMC Fatal hardware error.

0B9A

BMC not responding.

0B9B

Private I2C bus not responding.

0B9C

BMC internal exception.

0B9D

BMC A/D timeout error.

0B9E

SDR repository corrupt.

0B9F SEL

corrupt.

Turn off the power once and then on again to start the server. If
the error cannot be corrected, contact your service
representative.

0BB0

SMBIOS - SROM data read error.

0BB1

SMBIOS - SROM data checksum bad.

Contact your service representative.

0BC0

POST detected startup failure of 1st
Processor.

0BC1

POST detected startup failure of 2nd
Processor.

0BC2

POST detected startup failure of 3rd
Processor.

0BC3

POST detected startup failure of 4th
Processor.

Contact your service representative to replace the processor.