beautypg.com

2 se 923hp scanner specifications, User environment, Regulatory – Psion Teklogix Schnellstart- Anleitung 7525 User Manual

Page 340: Parameter se 923

background image

Chapter 10: Specifications
SE 923HP Scanner Specifications

310

Psion Teklogix WORKABOUT PRO With Windows Mobile 2003 SE User Manual

Figure 10.1 SE 1223 Scanner

10.3.2 SE 923HP Scanner Specifications

Interfaces:

12 position ZIF connector. Symbol Standard SSI
Interface with logic level serial data communications

plus trigger, beeper and decode LED signals

User Environment

Ambient Light, Artificial:

450 ft. candles (4,844 lux)

Ambient Light, Sunlight:

10,000 ft. candles (107,640 lux)

Operating Temperature:

-22° F to 140° F (-30° C to 60° C)

Storage Temperature:

-40° F to 140° F (-40° C to 60° C)

Humidity:

5% to 95% noncondensing

Power, Input Voltage:

5.0 VDC ± 10%

Power, Input Current:

110 mA typical

Power, Standby Current:

130 µA max.

Shock:

2,000 G

Regulatory

Laser Classification:

Intended for use in CDRH Class II and IEC Class 2
devices

Electrical Safety:

UL, VDE, and CUL recognized component laser

Parameter

SE 923

Light Source

Visible Laser Diode 650 nm

Scan Rate

39 (± 3) scans/sec (bi-directional)

Scan Angle

53º (typical)

Scan Patterns

Linear

Minimum Print Contrast

Minimum 25% absolute
dark/light reflectance measured at 650 nm

Symbologies

UPC/EAN, Code 128, Code 39, Code 93, I 2
of 5, Discrete 2 of 5, Codabar, MSI Plessey

Programmable Parameters

Laser On Time, Aim Duration, Power Mode,
Trigger Mode, Bi-directional Redundancy,
Symbology types/lengths, Data formatting,
Serial Parameters, Beeper Tone Scan Angle

Ambient Light:

Artificial: 450 ft. candles (4844 Lux)
Sunlight: 10000 ft. candles (107,640 Lux)

Operating Temperature:

-4º to 131ºF (-20º to 55ºC) chassis temperature

Storage Temperature:

-40° to 140°F (-40° to 60°C)