2 se 923hp scanner specifications, User environment, Regulatory – Psion Teklogix Schnellstart- Anleitung 7525 User Manual
Page 340: Parameter se 923
Chapter 10: Specifications
SE 923HP Scanner Specifications
310
Psion Teklogix WORKABOUT PRO With Windows Mobile 2003 SE User Manual
Figure 10.1 SE 1223 Scanner
10.3.2 SE 923HP Scanner Specifications
Interfaces:
12 position ZIF connector. Symbol Standard SSI
Interface with logic level serial data communications
plus trigger, beeper and decode LED signals
User Environment
Ambient Light, Artificial:
450 ft. candles (4,844 lux)
Ambient Light, Sunlight:
10,000 ft. candles (107,640 lux)
Operating Temperature:
-22° F to 140° F (-30° C to 60° C)
Storage Temperature:
-40° F to 140° F (-40° C to 60° C)
Humidity:
5% to 95% noncondensing
Power, Input Voltage:
5.0 VDC ± 10%
Power, Input Current:
110 mA typical
Power, Standby Current:
130 µA max.
Shock:
2,000 G
Regulatory
Laser Classification:
Intended for use in CDRH Class II and IEC Class 2
devices
Electrical Safety:
UL, VDE, and CUL recognized component laser
Parameter
SE 923
Light Source
Visible Laser Diode 650 nm
Scan Rate
39 (± 3) scans/sec (bi-directional)
Scan Angle
53º (typical)
Scan Patterns
Linear
Minimum Print Contrast
Minimum 25% absolute
dark/light reflectance measured at 650 nm
Symbologies
UPC/EAN, Code 128, Code 39, Code 93, I 2
of 5, Discrete 2 of 5, Codabar, MSI Plessey
Programmable Parameters
Laser On Time, Aim Duration, Power Mode,
Trigger Mode, Bi-directional Redundancy,
Symbology types/lengths, Data formatting,
Serial Parameters, Beeper Tone Scan Angle
Ambient Light:
Artificial: 450 ft. candles (4844 Lux)
Sunlight: 10000 ft. candles (107,640 Lux)
Operating Temperature:
-4º to 131ºF (-20º to 55ºC) chassis temperature
Storage Temperature:
-40° to 140°F (-40° to 60°C)