Maintaining The Vehicle Cradle

300

Psion Teklogix WORKABOUT PRO With Windows Mobile 2003 SE User Manual

To remove the unit, press firmly on the RELEASE button on the front face
of the unit until it releases from it latch. The hand-held will be slightly
raised so that it can be removed.

9.10.4 Maintaining The Vehicle Cradle

Two latches in the cradle hold the WORKABOUT PRO firmly in place. Although
these latches are designed for robustness and endurance, they will wear over time
and will no longer lock the hand-held securely in the cradle. For replacement parts
and instructions contact Psion Teklogix. Partial disassembly is required.

9.10.5 Powered Cradle Installation In High Voltage Vehicles

Warning:

Voltages exceeding 60VDC are considered hazardous. For powered
cradle installations on vehicles with batteries above this voltage,
ensure the powered cradle power connector is mounted in a dry
location on the vehicle, or that the connector is insulated with an
appropriate waterproof material after installation. The connector
must also be installed out of the vehicle operator’s reach. Exposing
an accessible power connector to water or other liquids could create
a hazardous situation resulting in serious injury or death.

Installation of powered cradles in vehicles that operate above 60VDC require
special consideration.
Due to the hazardous voltages present on these vehicles, it is necessary to ensure
that the powered cradle power supply cable connector is not accessible to the
vehicle operator, and does not get exposed to water or other liquids. This can be
accomplished in one of the following ways:

Ensure the power connector is installed in a dry location on the vehicle,
away from the vehicle operator’s reach (perhaps under a vehicle dash or in a
sealed housing).

Cover the power connector with a waterproof heat shrink material.

Wrap the connector securely with a waterproof electrical tape in an area out
of the vehicle operators reach.

All other installation requirements outlined in this document should also be
followed for High Voltage vehicles to insure safe installation and operation of the
powered cradle.