ERROR CODE E1029
Encoder rotation data is abnormal. (Jt XX)
Occurs when there is a difference (+2 rotations or more) between the rotation data in
the serial encoder data and the rotation data calculated using the incremental tech-
nique.
Power
circuit
Battery
Encoder
Encoder
1FG/1HG board
Robot
Controller
1KB board
Encoder I/F
Servo
CPU
Encoder +12 VDC power supply
⇒
Check connections at encoder, 1FG/1HG board, and separation harness.
⇒
Check for noise and shield integrity.
⇒
Ensure the 1KB board is properly seated into the card rack.
⇒
Check for continuity in the machine harness and separation harness.
⇒
Replace 1FG/1HG board.
⇒
Replace the 1KB board.
⇒
Replace the encoder.