TROUBLESHOOTING

D SERIES CONTROLLER

TROUBLESHOOTING AND COMPONENT REPLACEMENT

1-116

August 9, 2005

Ka a a

w s k

ERROR CODE E4004

Communication retry error.

Communication retry error during Host Communication I.

Main causes include:
1. No response after sending text.
2. After text is sent, NAK (resend request) exceeded the allowed number of retries.

Ensure communication protocol used for Host Communication I is correct.

Check the communication cable and replace as necessary.

_____________________________________________________________________

ERROR CODE E4005

Communication process was stopped.

During Host Communication I, a stop monitor command (ABORT, PCABORT, etc.) is
executed during execution of SEND/RECEIVE.

Re-execute the EXECUTE, PCEXECUTE, etc. command.

_____________________________________________________________________

ERROR CODE E4006

Receive no data after request.

During Host Communication I, text data is not received within the allowed time after the
data request is sent.

Ensure communication protocol used for Host Communication I is correct.

Check the communication cable and replace as necessary.

_____________________________________________________________________

ERROR CODE E4007

Receiving data is too long (MAX=255 character).

During Host Communication I, an attempt to receive a string with more than 255 charac-
ters is made.

Ensure communication protocol used for Host Communication I is correct.

_____________________________________________________________________

ERROR CODE E4008

Abnormal data (EOT) received in communication.

During Host Communication I, abnormal code (EOT) is received and the communication
process is stopped.

Ensure communication protocol used for Host Communication I is correct.

_____________________________________________________________________