ERROR CODE D2016
No response from the arm control board.
Request is sent to the 1KB board from the 1KA board and there is no response.
⇒
Reset error and if error recurs, replace the 1KA/1KB boards
.
_____________________________________________________________________
ERROR CODE D2017
No response from User I/F board.
1KA board software stopped.
Main causes include:
1. AS software is not installed correctly or is corrupt.
2. Defective 1KA board.
⇒
Reinstall correct AS software.
⇒
Replace 1KA board
.
_____________________________________________________________________
ERROR CODE D2018
[ARM CTRL BOARD] no response.
1KB board software stopped.
Main causes include:
1. AS software is not installed correctly or is corrupt.
2. Defective 1KB board.
⇒
Reinstall correct AS software.
⇒
Replace 1KB board
.
_____________________________________________________________________
ERROR CODE D2019
[ARM CTRL BOARD] servo software no response.
1KB board software stopped.
Main causes include:
1. Servo software is not installed correctly or is corrupt.
2. Defective 1KB board.
⇒
Reinstall correct 1KB board servo software to the 1KA board.
⇒
Replace 1KB board
.