Kawasaki D Series Controller MPVDCONTV113E-3 User Manual
Page 182

TROUBLESHOOTING
1-179
August 9, 2005
D SERIES CONTROLLER
TROUBLESHOOTING AND COMPONENT REPLACEMENT
Ka a a
w s k
ERROR CODE P1034
This program is not editable.
The auto load measurement program cannot be edited.
⇒
Use a program name that does not include the auto load measurement program
name.
_____________________________________________________________________
ERROR CODE P1035
Record inhibited. Set [record accept] and operate again.
Displayed when an attempt is made to enter data, but Inhibit Record in auxiliary function
0802 is set to inhibit.
⇒
Change the setting of the Inhibit Record in AUX 0802.
_____________________________________________________________________
ERROR CODE P1036
Program change inhibited. Set [Accept] and operate
again.
Displayed when an attempt is made to enter data, but Program Change in auxiliary
function 0802 is set to inhibit.
⇒
Change the setting of the Program Change in AUX 0802.
_____________________________________________________________________
ERROR CODE P1037
Program name cannot be called “calib_load_”.
⇒
Use a program name that does not include
“calib_load_
“.
_____________________________________________________________________
ERROR CODE P1038
Program does not exist.
Main causes include:
1. Non-existing program is selected.
2. Program check operation or cycle start is executed without a program selected.
⇒
Select an existing program before executing program check or cycle start.